TH9520
- High-resolution: 7-inch 800 × 480 dots, TFT-LCD display
- Insulation resistance test: maximum voltage can reach 5kV
- New-type high voltage test fixture
- Internal file storage and external U disk file saving
TH9520A
- High-resolution: 7-inch 800 × 480 dots, TFT-LCD display
- DC / IR automatic rapid discharge function
- New-type high voltage test fixture
- Internal file storage and external U disk file saving
TH9010
- Four-channel scanner supports contact check function
- 7-inch 800×480 dot-matrix, TFT-LCD display
- Enhanced security: electric shock protection
- Store 100 test files and each file can hold at most 20 testing
TH90101
- Expand each channel of TH9010 to 4 channels
- TH9010 supports 4 four-channel scanners at most
- One instrument can be extended to 128 channels
- Four-channel scanner supports contact check function
TH9010A
- 4-channel parallel output of withstand voltage
- Output: AC:5kV/10mA; DC: 6kV/5mA
- Insulation resistance test voltage: 0.10kV -1.00kV
- Four-channel scanner supports contact check function
TH90101A
- Expand each channel of TH9010A to 4 channels
- TH9010A supports 4 four-channel scanners
- One instrument can be extended to 64 channels
- Four-channel scanner supports contact check function
TH90102
- Expand the single-channel
- Withstand voltage insulation tester to 16 channels
- Can be connected to multiple expanders simultaneously
- Channel continuity detection function
TH9110
- High power: AC 5kV / 100mA / 500VA output
- Rear panel output function to facilitate automated production
- Storage: 100 files, up to 50 steps per file
- Electric shock protection function
TH9110A
- High power: AC 5kV / 100mA / 500VA output
- High resolution: 7 inch 800 × 480 dots, TFT-LCD display
- Rear panel output function to facilitate automated production
- One-key screen capture function
TH9120A
- High resolution: 7 inch 800 × 480 dots, TFT-LCD display
- Storage: 100 files, up to 50 steps per file
- Breakdown voltage test: AC can reach 10kV, resolution 10V
- Chinese and English menu operation interface
TH9120D
- High resolution: 7 inch 800 × 480 dots, TFT-LCD display
- One-click screen capture function
- Storage: 100 files, up to 50 steps per file
- Chinese and English menu operation interface
TH9201S
- Insulation resistance test voltage: 0.05-1kV
- TH9201S: 8-channel scanning AC/DC/IR
- 240×64 Dot-matrix graphic LCD display
- Built-in 8-channel matrix scanner for convenient use
TH9201
- Resistance test range: 0.1MΩ-50GΩ
- Insulation resistance test voltage: 0.05-1kV
- 240×64 Dot-matrix graphic LCD display
- Set voltage rising time, test time, and voltage dropping time
TH9201B
- Insulation resistance test voltage: 0.05-1kV
- Resistance test range: 0.1MΩ-50GΩ
- Set voltage rising time, test time, and voltage dropping time
- Current base number correction function
TH9320S8A
- Test voltage of IR: 0.10kV-1.00kV
- Provide 4 channels (-S4), 8 channels (-S8) scan interface
- Randomly set voltage rising time and testing time in 999.9
- Freely set waiting time for insulation resistance, Rapidly discharging and arc detection
TH9320S4A
- Provide 4 channels (-S4), 8 channels (-S8) scan interface
- Rapidly discharging and arc detection
- Randomly set voltage rising time and testing time in 999.9 seconds
- Freely set waiting time for insulation resistance
TH9320S8
- Provide 4 channels (-S4), 8 channels (-S8) scan interface
- 480×272 dot-matrix, TFT-LCD display
- Randomly set voltage rising time and testing time in 999.9 seconds
- Hold 20 testing steps, 4 testing modes selectable
TH9320S4
- Test voltage of IR: 0.10kV-1.00kV
- Provide 4 channels (-S4), 8 channels (-S8) scan interface
- Brand new operation interface and concise interface operation design
- Randomly set voltage rising time and testing time in 999.9 seconds
TH9320
- Test voltage of IR: 0.10kV-1.00kV
- Hold 20 testing steps; 4 testing modes selectable
- Brand new operation interface and concise interface operating design
- Randomly set voltage rising time and testing time in 999.9 seconds
TH9310
- Test range of IR: 0.1MΩ-9900MΩ
- 480×272 dot-matrix, TFT-LCD display
- Brand new operation interface and concise interface operating design
- Freely set waiting time for insulation resistance Lock
RS-232C interface as standard
TH9310A
- 480×272 dot-matrix, TFT-LCD display
- Hold 20 testing steps; 4 testing modes selectable
- Randomly set voltage rising time and testing time in 999.9 seconds
- Rapidly discharging and arc detection
TH9310B
- 480×272 dot-matrix, TFT-LCD display
- Rapidly discharging and arc detection
- Brand new operation interface and concise interface
- Randomly set voltage rising time and testing time in 999.9 seconds
TH9302C
- 6 test items or combinations, 9 test storage areas
- Contact check function (TH9302C, TH9302D)
- Relay input/output, HANDLER interface, support PLC
- External control interface, support synchronous or remote control
TH9302
- 6 test items or combinations, 9 test storage areas
- RS-232C interface as standard
Simple operability
- Relay input/output, HANDLER interface, support PLC
- External control interface, support synchronous or remote control
TH9302D
- Contact check function (TH9302C, TH9302D)
- Relay input/output, HANDLER interface, support PLC
- Voltage rise time: 0.1s-999.9s
Simple operability
- 6 test items or combinations, 9 test storage areas
TH9302B
- Contact check function (TH9302C, TH9302D)
- RS-232C interface as standard
- Relay input/output, HANDLER interface, support PLC
- External control interface, support synchronous or remote control
TL5502B
- Simultaneously display the tested (voltage, current, time)
- Continuously adjustable output voltage
- Unqualified sound and light alarm function
- With voltage breakdown protection function
TL5502A
- With manual, remote start and reset functions
- Simultaneously display the tested (voltage, current, time)
- With voltage breakdown protection function
- Unqualified sound and light alarm function
TL5510A
- Simultaneously display the tested (voltage, current, time)
- Continuously adjustable output voltage
- With voltage breakdown protection function
- Unqualified sound and light alarm function
TL5520B
- Simultaneously display the tested (voltage, current, time)
- With manual, remote start and reset functions
- Unqualified sound and light alarm function
- With voltage breakdown protection function
TL5605A
- Simultaneously display the tested (voltage, current, time)
- With manual, remote start and reset functions
- Unqualified sound and light alarm function
- With voltage breakdown protection function
TH9410A
- Grounding resistance range: 0-600mΩ
- Four-terminal test mode to ensure test accuracy
- Keyboard lock function to prevent misoperation
- Safety lock function to prevent the instrument
TH9403
- Constant current linear amplifier output
- Front panel software calibration, high accuracy
- TH9403 and TH9301 are connected to form a two-in-one withstand voltage
- Keyboard lock function
TL5703
- Grounding resistance range: 0-200/600mΩ
- Test current, test resistance and test time are displayed at the same time
- Test time can be set arbitrarily
- The test alarm value can be set continuously and arbitrarily
TH9411A
- Â
Â
- Â
Â
- Â Â Â Â Â Â Â Â Â No data found
- Â
Â
TL5802
- Simultaneous display of test voltage, leakage current and test time
- Automatic phase conversion
- Over-limit sound and light alarm
- Flexible integrated and split structure suitable for testing equipment
TL5802S
- Simultaneous display of test voltage, leakage current
- Automatic phase conversion
- Measuring bandwidth up to 1MHz
- Flexible integrated and split structure suitable for testing equipment
TH2131
- Large 4 1/2 7-segment LED display
- Input impedance 100MΩ±1%
- DC voltage 0-12.000 (kV)
- AC voltage 0-10.000 (kV)